pump packages for fluid coolers

Main Menu - chillers home | applications | client list | load sizing | sitemap | get a quote | links
Products - portable chillers | central chillers | cooling towers | tank sets | engineered solutions


-

Pump Packages for Chillers and Fluid Coolers

Temperature Corporation manufactures pump packages for chillers and fluid coolers. These packages are for anywhere you want pumping. There are seven models to choose from.

Drawing

MODEL

MAXIMUM FLOW

PUMP HP

SUCTION

#

GPM AT

GPM AT

GPM AT

3500

DISCHARGE

 

80 HF

100 HF

120 HF

RPM

INCHES

           

DP-1.5 x 1.5   

35

20

NA

1 1/2 hp 

1 1/2” 

DP-2 x 2   

45

35

NA

2 hp

2"

DP-3 x 3   

80

50

35

3 hp

2"

DP-5 x 5   

180

130

85

5 hp

3"

DP-7.5 x 7.5   

250

200

100

7 1/2 hp

4"

DP-10 x 10   

350

275

175

10 hp

4"

DP-15 x 15   

450

40

350

15 hp

6"


MODEL

MAXIMUM FLOW

PUMP HP

SUCTION

#

GPM AT

GPM AT

GPM AT

1750

DISCHARGE

 

80 HF

100 HF

120 HF

RPM

INCHES

           

DP-5 x 5   

150

NA

85

5 hp

3"

DP-7.5 x 7.5   

200

NA

NA

7 1/2 hp

3"

DP-10 x 10   

325

190

NA

10 hp

4"

LDP-7.5 x 7.5   

250

150

NA

7 1/2 hp

4"

LDPA-10 x 10   

350

NA

NA

10 hp

4"

LDPB-10 x 10   

NA

225

150

10 hp

4"

1 - Maximum flow may vary depending on selection of pump model.
2 - Recommended maximum flow through system based on 8’ to 8 ½’ per second velocity:

1 ½” –   40 gpm
2”    –  90 gpm
2 ½” – 125 gpm
3”    – 200 gpm
4”    – 325 gpm
6”     –  750 gpm

3 - We can supply pumps in 380/3/50 hertz for export.

4 - OPTIONS AVAILABLE:    
ASME COMPRESSION TANKS

10 gallon tank, 10” diameter - $ 0,000.00
24 gallon tank, 20” diameter - $ 0,000.00  

PURGAIR FITTING WITH 3/4" AIR VENT:

TRIPLE DUTY DISCHARGE VALVES: (both installed)

2"

2"

2 1/2"

2 1/2"

3"

3"

4"

4"

MODEL DP- 30 X 30 DOUBLE PUMP PACKAGE WITH COMPRESSION TANK AND AIR PURGE COMPLETE WITH THE FOLLOWING:

TWO PUMPS: Each pump is an end fed centrifugal stamped stainless steel pump with a stainless steel impeller, each pump will supply 586 gpm at 110 HF (48 psi) and is close coupled to a 30 hp 1750 rpm TEFC pump motor.

PUMP FITTINGS: 6" connections with inlet flow switch and 6" pump suction and discharge headers, each pump complete with suction shut-off valve, suction strainer, suction flange or union, discharge flange or union, discharge check valve, discharge flow control valve, pressure gauge with shut-off valve and discharge thermometer with brass well.

One pump can be removed for service while the other is operating.

COMPRESSION TANK SYSTEM: Complete with a mild steel ASME approved 00 gallon compression tank, a 6" air purge, a dual pressure reducing fill valve and pressure relief valve.

HOUSING: Galvanized steel watertight housing with removable panels for service.

CONTROL PANEL: Weather proof control panel complete with pump motor starters with thermal overloads, pump three phase fuses, control transformer with primary and secondary fuses, power on light, pump run and fail lights, local-off-remote switch for remote starting of pump package, one (1) flow switch and two (2) hand-off-auto switches for with an alternating relay for starting of second pump if first pump fails and an automatic 24 hour lead - lag timer for equal run time on pumps. SIZE: Rugged bolted galvanized steel frame, control box, top and side panels.

FRAMESIZE: 54"l x 36"w x 32 1/2"h. VOLTAGE: 460V, 3 phase, 60 hertz.

FULL LOAD AMPS: 37.5 amps with both pumps operating. MCA: 86 amps with both pumps operating.

RECOMMENDED FUSE SIZE: 100 amps with both pumps operating.

WARRANTY: 1 YEAR parts warranty on the whole unit.

OPTIONS (add): EXPANSION TANK: ASME certified 15 gallon compression tank complete with airtrol fitting, pressure relief, inlet connection with shut-off valve and union, shipped loose for installation in main header an air purge.

Single and Dual Tank Sets [click to enlarge]

1. Single Pump Tank Set:
Single pump tank set can be used where the process water flow is constant and the flow is the same as the chiller.

Not recommended for cooling towers in a cold climate where the cooling tower can freeze.

Dual Pump tank set is the most common type and has two pumps. One pump is dedicated to the cooling towers or chillers to maintain constant flow required by them to ensure maximum efficiency and safe operation.

Contact us today: Tel: 905.513.8310 - Email: sales@temperaturecorporation.com

For your convenience we now offer payment options by and

 
chillers home | client list | load sizing | sitemap | get a quote | links
a

Copyright ® 2006 | Temperature Corporation | All Rights Reserved

a
Temperature Corporation ~ 111 Esna Park Drive, Unit 7 ~ Markham, Ontario, L3R 1H2
Tel: 905. 513. 8310 ~ Fax: 905. 513. 8358 ~ Email: sales@temperaturecorporation.com