Single and Dual Tank Sets [click to enlarge] |
1.
Single Pump Tank Set:
Single pump tank set can be used where the process
water flow is constant and the flow is the same as the chiller.
Not recommended for cooling towers in a cold climate where the cooling tower can freeze.
Dual Pump tank set is the most common type and has two pumps. One pump is dedicated to the cooling towers or chillers to maintain constant flow required by them to ensure maximum efficiency and safe operation.
The second pump is dedicated to the process to supply higher flows than the cooling tower or chillers would normally allow, and higher water pressure required by the varying process equipment demand.
![]() |
||
|
Three Pump Standby |
2.
Three Pump Standby Tank Set:
Three pump standby is the most common method to add a standby pump to
the tank set. A third pump, the same capacity as the process pump, is
installed on the frame between the two existing pumps with a common discharge
header. Two isolation valves are located one on either side of the standby
pump, if the process pump fails its discharge valve is closed, the isolation
on the process header side is opened and you are in operation and the
defective pump can be repaired. If the chiller or tower pump fails the
same procedure is followed.
Structural Steel Supports
Structural Steel Supports can be welded to both the chiller and tower
pump tanks so that chillers can be mounted above either.
![]() |
||
|
Structural Supports |
3.
Multiple Pump Tank Sets:
Multiple pump tank set has two or more pumps for the process
and the cooling equipment. When high water flows are required, two or
three industrial pumps will supply the required flow and save on total
horsepower and pump cost.
![]() |
||
|
Multiple Pump Tank Sets |
These ECONOMICAL all stainless steel tanks and pump supports are available in dual and three pump standby configurations. The Three Pump is the most common method with a standby pump and discharge header added to the tank set. The third pump, the same capacity as the process pump, is installed on the frame between the two existing pumps with a common discharge header. Available as a chilled water tank or cooling tower tank in 25, 50, 75 and 100 ton models.
|
|
Options For Both Models
|